What This Part Does

This electronic ignition control module operates and monitors the fireplace ignition sequence in an IPI (Intermittent Pilot Ignition) system.

When the fireplace receives a call for heat from a wall switch, thermostat, or remote control, the module begins the ignition cycle by powering the spark igniter and coordinating gas flow through the valve.

The module monitors flame rectification signals from the pilot assembly to verify ignition. Once pilot flame is proven, the module signals the gas valve to open the main burner.

This control module also manages safety shutdown functions. If ignition fails, flame is lost, or a fault condition is detected, the module will stop gas flow and place the system into safety lockout.

Electronic control modules are used in modern IPI fireplace systems and typically operate with battery backup or household power.


Not sure if this is the right part?

Before ordering, check the following:

  • Locate your model number (typically behind the lower louver or inside the control compartment)
  • Confirm your unit uses a Electronic system
  • Compare your existing control module to the images provided

⚠️ This part is NOT for a different ignition/control system systems

Compatible Models

Heatilator Gas Fireplaces:
6000CBV-IPI
6000CL-IPILP-S
6000CL-IPILP-T
6000CL-IPI-T
6000CLX-IPILP-S
6000CLX-IPILP-T
6000CLX-IPI-S
6000CLX-IPI-T
8000CBV-IPI
8000C-IPI
8000C-IPILP
8000CL-IPILP-S
8000CL-IPILP-T
8000CL-IPI-S
8000CL-IPI-T
8000CLX-IPILP-S
8000CLX-IPILP-T
8000CLX-IPI-S
8000CLX-IPI-T
BV4236DBI
BV4236DBI-B
BV4842DBI
BV4842DBI-B
CARODG36I
CARODG36I-B
CARODG36IL
CARODG42I
CARODG42I-B
CARODG42IL
CD4236ILR-C
CD4236ILR-D
CD4236IR-C
CD4236IR-D
CD4842ILR-C
CD4842ILR-D
CD4842IR-C
CD4842IR-D
CNXT4236IH-C
CNXT4236IH-D
CNXT4236ILH-C
CNXT4236ILT-C
CNXT4236IT-C
CNXT4236IT-D
CNXT4842IH-C
CNXT4842IH-D
CNXT4842ILH-C
CNXT4842ILT-C
CNXT4842IT-C
CNXT4842IT-D
CRAVE4836
CRAVE4836-B
CRAVE4836ST
CRAVE4836ST-B
CRAVE6048
CRAVE6048-B
CRAVE6048ST
CRAVE6048ST-B
CRAVE6048ST-LP
CRAVE7260
CRAVE7260-B
CRAVE7260ST
CRAVE7260ST-B
CRAVE8472
CRAVE8472-B
CRAVE8472ST
CRAVE8472ST-B
DBDV36IL
DBDV36IN
DBDV36PLATIL
DBDV36PLATIN
DBDV42IL
DBDV42IN
DBDV42PLATIL
DBDV42PLATIN
HEIR36H
HEIR36T
HEIR42H
HEIR42T
HEIR50H
HEIR50T
ION-H7
ION-S7
ION-V7
LUX36
LUX42
MEZZO36
MEZZO36-B
MEZZO36ST
MEZZO36ST-B
MEZZO48
MEZZO48-B
MEZZO48ST
MEZZO48ST-B
MEZZO60
MEZZO60-B
MEZZO60ST
MEZZO60ST-B
MEZZO72
MEZZO72-B
MEZZO72ST
MEZZO72ST-B
NEVO3630I
NEVO3630I-B
NEVO4236I
NEVO4236I-B
NNXT3933I
NNXT3933IF
NNXT3933IF-B
NNXT3933IL
NNXT3933ILF
NNXT3933ILF-B
NNXT4236I
NNXT4236IF
NNXT4236IF-B
NNXT4236IL
NNXT4236ILF
NNXT4236ILF-B
REVO-H31
REVO-S21
REVO-V12
SL-3X
SL-5X
SL-5XLP
SL-7X
SL-7XLP
SL-9X

Heatilator Gas Inserts:
COSMO-I30
COSMO-I30-C
COSMO-I35
COSMO-I35-C
ESCAPE-I30-C
ESCAPE-I30FB
ESCAPE-I30FB-LP
ESCAPE-I30LP-C
ESCAPE-I35-C
ESCAPE-I35FB
ESCAPE-I35FB-LP
ESCAPE-I35LP-C
GRAND-I35
QFI30
QFI30-C
QFI30FB
QFI30FB-C
QFI35
QFI35-C
QFI35FB
QFI35FB-C
SUPREME-I30
SUPREME-I30-NZ

Heat-N-Glo Gas Fireplaces:
6000C-IPI
6000C-IPILP
6000CL-IPI-S
TRUE-36C
TRUE-36H
TRUE-36S
TRUE-42C
TRUE-42H
TRUE-42S
TRUE-50C
TRUE-50H
TRUE-50S

Heat-N-Glo Gas Inserts:
ESCAPE-I30-F
ESCAPE-I30LP-F
ESCAPE-I35-F
ESCAPE-I35LP-F
GRAND-I35-C
SUPREME-I30-C

Majestic Gas Fireplaces:
ECHEL36IN
ECHEL36STIN
ECHEL48IN
ECHEL48STIN
ECHEL60IN
ECHEL72IN

Majestic Gas Inserts:
MDVI30IL
MDVI30IN
MDVI35IL
MDVI35IN

System Type

This is an electronic ignition system, commonly called an IPI system or intermittent pilot ignition system. Instead of keeping a pilot flame burning continuously, the fireplace lights the pilot only when there is a call for heat.

IPI systems use a control module to manage ignition, flame sensing, gas valve operation, and safety shutdown functions.

This system commonly includes:

  • Control module — controls spark, flame sensing, and gas valve operation.
  • Electronic gas valve — opens and closes gas flow to the pilot and main burner.
  • Igniter / flame sensor assembly — creates spark and confirms flame presence.
  • Battery backup or power supply — provides operating power for ignition and control functions.

These systems offer improved efficiency, remote-control compatibility, and added safety features, but they also include more electronic components than a millivolt system.

Common Problems This Control Module May Fix

  • Fireplace will not light or start
  • No spark at the pilot assembly
  • Pilot lights but main burner will not ignite
  • Intermittent operation or random shutdowns
  • Module clicks continuously without ignition
  • No response from wall switch, thermostat, or remote
  • System locks out after failed ignition attempts
  • Burner shuts off unexpectedly during operation

The control module is the main electronic controller for the fireplace ignition system. A failed module can prevent proper communication between the pilot assembly, gas valve, flame sensor, and wall controls.

Before replacing the module, also inspect the pilot assembly, wiring harness, grounding, batteries, and gas valve, as these components can cause similar symptoms.

Warranty Information

This product includes a 12-month warranty from the date of purchase. This warranty covers defects in materials or workmanship under normal operating conditions.

Fireplace components must be properly installed and matched to the correct system (millivolt vs IPI, natural gas vs propane).

This warranty does NOT cover:
• Improper installation or incorrect application
• Use with the wrong gas type (NG vs LP)
• Misdiagnosis of the issue
• Damage caused by other failing components
• Normal wear and tear
• Labor, service, or diagnostic time

Because many fireplace issues can be caused by multiple components, we strongly recommend confirming the diagnosis before replacing parts.

We are happy to assist with this. Proof of purchase is required for all warranty claims. Please contact us prior to removal or replacement of the part so we can help verify the issue and guide the warranty process.

How difficult is this part to replace?

Replacing a fireplace control module is generally considered a moderate repair that involves working with low-voltage wiring and electronic ignition components.

The process typically requires access to the control compartment, disconnecting wiring harnesses, and properly reconnecting the replacement module according to the manufacturer’s specifications.

Care should be taken to avoid wiring errors or damage to sensitive electronic components during installation.

How do I know if this part is bad?

Common signs of a failing control module include no spark during ignition, intermittent operation, repeated system lockouts, or the fireplace failing to respond to a wall switch, remote, or thermostat.

In some cases, the module may fail to send power to the igniter or gas valve, preventing the pilot or burner from lighting properly.

Before replacing the control module, it is important to verify that the igniter, flame sensor, wiring, power supply, and gas valve are functioning correctly, as these components can produce similar symptoms.

Do I need any special tools to install this?

Most control module replacements can be performed using basic hand tools such as screwdrivers and nut drivers. Some installations may also require access to wiring connectors or mounting brackets inside the fireplace.

It is important to verify all wiring connections are installed correctly and securely, as improper wiring can prevent ignition or damage system components.

Always disconnect power to the fireplace before servicing electronic components.

Is this a safe DIY repair?

Control module replacement is generally safer than repairs involving gas lines, but it still requires working with electrical and ignition components inside the fireplace.

Improper wiring, incorrect setup, or failure to follow manufacturer instructions can prevent proper ignition or cause unsafe operation. Care should also be taken to avoid damaging sensitive electronic components during installation.

If you are comfortable working with low-voltage wiring and fireplace components, this may be a manageable repair. When in doubt, installation should be performed by a qualified technician.